PR9112 Entelijan Presyon Kalibratè

Deskripsyon kout:

Nouvo kalite pwodwi (akò HART ka pote), Double-ranje likid kristal ekspozisyon ak ekleraj, Gen nèf inite presyon ka chanje selon bezwen aktyèl yo nan itilizatè yo, ak fonksyon pwodiksyon DC24V, Konekte ak divès kalite estrès ak trè apwopriye pou itilizasyon jaden ak laboratwa.


Pwodwi detay

Tags pwodwi

Paramèt teknik

Modèl

PR9112 Entelijan Presyon Kalibratè

Mezi presyon

Ranje Mezi

(-0.1~250)Mpa

Montre presizyon

±0.05%FS, ±0.02%FS

Mezi kouran elektrik

Range

± 30.0000mA

Sansiblite

0.1uA

Presizyon

±(0.01%R.D+0.003%FS)

Mezi Voltage

Range

± 30.0000V

Sansiblite

0.1mV

Presizyon

±(0.01%RD +0.003%FS)

Chanje Valè

Yon gwoup mezi pouvwa / panne

Fonksyon pwodiksyon

Pwodiksyon aktyèl dirèk

DC24V±0.5V

Anviwònman fonksyònman

Tanperati travay

(-20~50)℃

Tanperati relatif

<95%

Tanperati Depo

(-30~80)℃

Konfigirasyon ekipman pou pouvwa

Mòd ekipman pou pouvwa

Batri ityòm oswa ekipman pou pouvwa

Tan fonksyònman batri

60 èdtan (24V san chaj)

Tan pou chaje

Apeprè 4 èdtan

Lòt endikatè

Gwosè

115mm × 45mm × 180mm

Koòdone kominikasyon

espesyalize twa-nwayo ploge avyasyon

Pwa

0.8KG

Aplikasyon prensipal:

1.Calibrate presyon (presyon diferans) transmetè

2.Calibrate switch presyon

3.Verify kalib presyon an presizyon, kalib presyon jeneral.

Karakteristik pwodwi:

1.Built-an fonksyon manyèl operatè, transmetè presyon entèlijan HART ka kalibre.(si ou vle)

2.Double-ranje ekspozisyon kristal likid ak ekleraj.

3.mmH2O、mmHg、psi、kPa、MPa、Pa、mbar、bar、kgf/c㎡, chanje ant nèf inite presyon.

4.Avèk fonksyon pwodiksyon DC24V.

5.With aktyèl, mezi vòltaj.

6.Measuring ak chanje volim.

7.Avèk koòdone kominikasyon.(si ou vle)

8. Kapasite depo: total 30 pcs dosye, (50 dosye done nan chak dosye)

9.Big ekran kristal likid ekspozisyon

Konfigirasyon lojisyèl:

Lojisyèl PR9112S nan sistèm verifikasyon presyon se lojisyèl sipò nan pwodwi seri kalibratè presyon dijital nou an nan konpayi nou an, dosye koleksyon done yo ka fèt, Oto pwodwi fòm, Otomatik kalkil erè, sètifika enprime.

1.Woutin Presyon Range Seleksyon Tablo

Non.

Ranje presyon

Kalite

Klas presizyon

01

(-100 ~ 0) kPa

G

0.02/0.05

02

(0 ~ 60) Pa

G

0.2/0.05

03

(0 ~ 250) Pa

G

0.2/0.05

04

(0 ~ 1) kPa

G

0.05/0.1

05

(0 ~ 2) kPa

G

0.05/0.1

06

(0 ~ 2.5) kPa

G

0.05/0.1

07

(0 ~ 5) kPa

G

0.05/0.1

08

(0 ~ 10) kPa

G

0.05/0.1

09

(0 ~ 16) kPa

G

0.05/0.1

10

(0 ~ 25) kPa

G

0.05/0.1

11

(0 ~ 40) kPa

G

0.05/0.1

12

(0 ~ 60) kPa

G

0.05/0.1

13

(0 ~ 100) kPa

G

0.05/0.1

14

(0 ~ 160) kPa

G/L

0.02/0.05

15

(0 ~ 250) kPa

G/L

0.02/0.05

16

(0 ~ 400) kPa

G/L

0.02/0.05

17

(0 ~ 600) kPa

G/L

0.02/0.05

18

(0 ~ 1) MPa

G/L

0.02/0.05

19

(0 ~ 1.6) MPa

G/L

0.02/0.05

20

(0 ~ 2.5) MPa

G/L

0.02/0.05

21

(0 ~ 4) MPa

G/L

0.02/0.05

22

(0 ~ 6) MPa

G/L

0.02/0.05

23

(0 ~ 10) MPa

G/L

0.02/0.05

24

(0 ~ 16) MPa

G/L

0.02/0.05

25

(0 ~ 25) MPa

G/L

0.02/0.05

26

(0 ~ 40) MPa

G/L

0.02/0.05

27

(0 ~ 60) MPa

G/L

0.05/0.1

28

(0 ~ 100) MPa

G/L

0.05/0.1

29

(0 ~ 160) MPa

G/L

0.05/0.1

30

(0 ~ 250) MPa

G/L

0.05/0.1

Remak: G=GasL=Likid

2.Tablo seleksyon ranje presyon konpoze:

Non.

Ranje presyon

Kalite

Klas presizyon

01

± 60 Pa

G

0.2/0.5

02

± 160 Pa

G

0.2/0.5

03

± 250 Pa

G

0.2/0.5

04

± 500 Pa

G

0.2/0.5

05

± 1kPa

G

0.05/0.1

06

± 2kPa

G

0.05/0.1

07

± 2.5 kPa

G

0.05/0.1

08

± 5kPa

G

0.05/0.1

09

± 10kPa

G

0.05/0.1

10

± 16kPa

G

0.05/0.1

11

± 25kPa

G

0.05/0.1

12

± 40kPa

G

0.05/0.1

13

± 60kPa

G

0.05/0.1

14

± 100kPa

G

0.02/0.05

15

(-100 ~ 160) kPa

G/L

0.02/0.05

16

(-100 ~ 250) kPa

G/L

0.02/0.05

17

(-100 ~ 400) kPa

G/L

0.02/0.05

18

(-100 ~ 600) kPa

G/L

0.02/0.05

19

(-0.1 ~ 1) Mpa

G/L

0.02/0.05

20

(-0.1 ~ 1.6) Mpa

G/L

0.02/0.05

21

(-0.1 ~ 2.5) Mpa

G/L

0.02/0.05

Remak:

1.Pasyèl ranje ka fè absoliman presyon

2.Otomatik tanperati konpansasyon ranje: (-20 ~ 50 ℃)

3.Pressure transfè mwayen mande ki pa korozivite