PR9112 Entelijan Presyon Kalibratè
Paramèt teknik
Modèl | PR9112 Entelijan Presyon Kalibratè | |
Mezi presyon | Ranje Mezi | (-0.1~250)Mpa |
Montre presizyon | ±0.05%FS, ±0.02%FS | |
Mezi kouran elektrik | Range | ± 30.0000mA |
Sansiblite | 0.1uA | |
Presizyon | ±(0.01%R.D+0.003%FS) | |
Mezi Voltage | Range | ± 30.0000V |
Sansiblite | 0.1mV | |
Presizyon | ±(0.01%RD +0.003%FS) | |
Chanje Valè | Yon gwoup mezi pouvwa / panne | |
Fonksyon pwodiksyon | Pwodiksyon aktyèl dirèk | DC24V±0.5V |
Anviwònman fonksyònman | Tanperati travay | (-20~50)℃ |
Tanperati relatif | <95% | |
Tanperati Depo | (-30~80)℃ | |
Konfigirasyon ekipman pou pouvwa | Mòd ekipman pou pouvwa | Batri ityòm oswa ekipman pou pouvwa |
Tan fonksyònman batri | 60 èdtan (24V san chaj) | |
Tan pou chaje | Apeprè 4 èdtan | |
Lòt endikatè | Gwosè | 115mm × 45mm × 180mm |
Koòdone kominikasyon | espesyalize twa-nwayo ploge avyasyon | |
Pwa | 0.8KG |
Aplikasyon prensipal:
1.Calibrate presyon (presyon diferans) transmetè
2.Calibrate switch presyon
3.Verify kalib presyon an presizyon, kalib presyon jeneral.
Karakteristik pwodwi:
1.Built-an fonksyon manyèl operatè, transmetè presyon entèlijan HART ka kalibre.(si ou vle)
2.Double-ranje ekspozisyon kristal likid ak ekleraj.
3.mmH2O、mmHg、psi、kPa、MPa、Pa、mbar、bar、kgf/c㎡, chanje ant nèf inite presyon.
4.Avèk fonksyon pwodiksyon DC24V.
5.With aktyèl, mezi vòltaj.
6.Measuring ak chanje volim.
7.Avèk koòdone kominikasyon.(si ou vle)
8. Kapasite depo: total 30 pcs dosye, (50 dosye done nan chak dosye)
9.Big ekran kristal likid ekspozisyon
Konfigirasyon lojisyèl:
Lojisyèl PR9112S nan sistèm verifikasyon presyon se lojisyèl sipò nan pwodwi seri kalibratè presyon dijital nou an nan konpayi nou an, dosye koleksyon done yo ka fèt, Oto pwodwi fòm, Otomatik kalkil erè, sètifika enprime.
1.Woutin Presyon Range Seleksyon Tablo
Non. | Ranje presyon | Kalite | Klas presizyon |
01 | (-100 ~ 0) kPa | G | 0.02/0.05 |
02 | (0 ~ 60) Pa | G | 0.2/0.05 |
03 | (0 ~ 250) Pa | G | 0.2/0.05 |
04 | (0 ~ 1) kPa | G | 0.05/0.1 |
05 | (0 ~ 2) kPa | G | 0.05/0.1 |
06 | (0 ~ 2.5) kPa | G | 0.05/0.1 |
07 | (0 ~ 5) kPa | G | 0.05/0.1 |
08 | (0 ~ 10) kPa | G | 0.05/0.1 |
09 | (0 ~ 16) kPa | G | 0.05/0.1 |
10 | (0 ~ 25) kPa | G | 0.05/0.1 |
11 | (0 ~ 40) kPa | G | 0.05/0.1 |
12 | (0 ~ 60) kPa | G | 0.05/0.1 |
13 | (0 ~ 100) kPa | G | 0.05/0.1 |
14 | (0 ~ 160) kPa | G/L | 0.02/0.05 |
15 | (0 ~ 250) kPa | G/L | 0.02/0.05 |
16 | (0 ~ 400) kPa | G/L | 0.02/0.05 |
17 | (0 ~ 600) kPa | G/L | 0.02/0.05 |
18 | (0 ~ 1) MPa | G/L | 0.02/0.05 |
19 | (0 ~ 1.6) MPa | G/L | 0.02/0.05 |
20 | (0 ~ 2.5) MPa | G/L | 0.02/0.05 |
21 | (0 ~ 4) MPa | G/L | 0.02/0.05 |
22 | (0 ~ 6) MPa | G/L | 0.02/0.05 |
23 | (0 ~ 10) MPa | G/L | 0.02/0.05 |
24 | (0 ~ 16) MPa | G/L | 0.02/0.05 |
25 | (0 ~ 25) MPa | G/L | 0.02/0.05 |
26 | (0 ~ 40) MPa | G/L | 0.02/0.05 |
27 | (0 ~ 60) MPa | G/L | 0.05/0.1 |
28 | (0 ~ 100) MPa | G/L | 0.05/0.1 |
29 | (0 ~ 160) MPa | G/L | 0.05/0.1 |
30 | (0 ~ 250) MPa | G/L | 0.05/0.1 |
Remak: G=GasL=Likid
2.Tablo seleksyon ranje presyon konpoze:
Non. | Ranje presyon | Kalite | Klas presizyon |
01 | ± 60 Pa | G | 0.2/0.5 |
02 | ± 160 Pa | G | 0.2/0.5 |
03 | ± 250 Pa | G | 0.2/0.5 |
04 | ± 500 Pa | G | 0.2/0.5 |
05 | ± 1kPa | G | 0.05/0.1 |
06 | ± 2kPa | G | 0.05/0.1 |
07 | ± 2.5 kPa | G | 0.05/0.1 |
08 | ± 5kPa | G | 0.05/0.1 |
09 | ± 10kPa | G | 0.05/0.1 |
10 | ± 16kPa | G | 0.05/0.1 |
11 | ± 25kPa | G | 0.05/0.1 |
12 | ± 40kPa | G | 0.05/0.1 |
13 | ± 60kPa | G | 0.05/0.1 |
14 | ± 100kPa | G | 0.02/0.05 |
15 | (-100 ~ 160) kPa | G/L | 0.02/0.05 |
16 | (-100 ~ 250) kPa | G/L | 0.02/0.05 |
17 | (-100 ~ 400) kPa | G/L | 0.02/0.05 |
18 | (-100 ~ 600) kPa | G/L | 0.02/0.05 |
19 | (-0.1 ~ 1) Mpa | G/L | 0.02/0.05 |
20 | (-0.1 ~ 1.6) Mpa | G/L | 0.02/0.05 |
21 | (-0.1 ~ 2.5) Mpa | G/L | 0.02/0.05 |
Remak:
1.Pasyèl ranje ka fè absoliman presyon
2.Otomatik tanperati konpansasyon ranje: (-20 ~ 50 ℃)
3.Pressure transfè mwayen mande ki pa korozivite